Maxx Air · Exhaust fan · Small airflow

Maxx Air IF14UPS 14-Inch Exhaust Fan

Maxx Air IF14UPS 14-Inch Exhaust Fan

Tap the photo to enlarge it.

Photos: Amazon product listing ↗ · refreshed Sep 16, 2026

Airflow (high)
1,400 CFM
Manufacturer source
Blade diameter
14 in
Manufacturer source

The Maxx Air IF14UPS is a 14-inch, one-speed wall exhaust fan with 1,400 CFM listed by the current manufacturer page.

What works

  • The exact IF14UPS plain-carton alias is listed on the current manufacturer page
  • Current specifications list 1,400 CFM, 120V, 2.65A, 310W, a 7.5-foot cord, and automatic shutter

What doesn't

  • The page requires 4.5 square feet of net-free intake area
  • A replacement-motor page lists different motor data and should not be blended with the assembled-fan specification

Who it's for

Good fit

  • A fixed 14-inch wall-exhaust installation with a documented 17.25-inch square rough opening and adequate intake
  • Ordinary heat, humidity, or stale-air removal where its 120V plug-in configuration fits the site

Look elsewhere if

  • Hazardous fumes or chemicals
  • A system without a planned replacement-air path

The current page confirms the plain-carton IF14UPS

Maxx Air’s 14-inch heavy-duty exhaust-fan page lists IF14UPS as the plain-carton alias. For the assembled fan, it lists up to 1,400 CFM, a one-speed totally enclosed PSC motor, 1/5 HP, 120V/60 Hz, 2.65A, 310W, and 1,130 RPM. It also lists a 27-pound unit, 20.4 × 20.4 × 12.75-inch H × W × D dimensions, a 7.5-foot three-prong cord, an automatic shutter, and a one-year limited warranty.

The wall opening is part of the purchase decision: Maxx Air specifies 17.25 × 17.25 inches and 4.5 square feet of net-free intake area. Plan the intake and exterior discharge before treating the 1,400-CFM figure as an installed result. A blocked louver, restricted intake, or poor air path can reduce delivered flow.

Do not blend the replacement motor with the whole fan

Maxx Air also offers a replacement motor compatible with IF14 and IF14UPS. Its listed motor ratings differ from the assembled-fan page. That may reflect a replacement or later component configuration; it does not revise the whole-fan specifications above. Use the assembled IF14UPS page and the actual unit nameplate for selection, then use a replacement part only after confirming compatibility.

The manufacturer says this fan is not intended for hazardous fumes or chemicals. For ordinary ventilation, compare it with other industrial exhaust fans using opening, intake, electrical, and location details. The CFM calculator can examine a stated room-flow assumption, but it cannot replace the intake and installation requirements for the real wall system.

Verdict

Choose the IF14UPS for a properly planned small wall-exhaust opening when its documented opening, intake, and electrical details fit. Use the assembled-fan page for selection, not the specifications of a replacement component.

Questions people ask

What opening does the IF14UPS require?
Maxx Air lists a 17.25-by-17.25-inch rough opening. Confirm the actual wall construction and installation instructions before cutting.
Does the IF14UPS need intake air?
Yes. The manufacturer lists 4.5 square feet of net-free intake area for this fan.

Before you buy

Installation and buying checks

Use these questions to verify the exact configuration. Linked facts are cited; unlisted details stay questions.

  1. Mounting and support

    What mounting method and hardware does the exact unit require?

  2. Clearance and handling

    Do the listed physical details leave enough clearance for installation, adjustment, and service?

  3. Electrical match

    Does the documented electrical information match the planned supply? Confirm the installed unit’s nameplate and installation instructions before connecting it.

  4. Airflow at the job

    Is the listed airflow rated at an operating point that matches the job after placement, obstructions, and system resistance are considered?

  5. Location requirements

    Do the documented location and guard details match the conditions and rules at the installation site? Check the manufacturer instructions for the exact configuration.

Put 1,400 CFM in context

The Maxx Air IF14UPS 14-Inch Exhaust Fan has a listed airflow of 1,400 cubic feet per minute. The table compares this rated volume with example room volumes. It does not measure fresh-air exchange, air speed at your body, or room coverage.

RoomSizeNominal room volumes / hourNominal pass interval
One-car garage22 × 12 × 9 ft · 2,376 ft³35×1.7 min
Two-car garage22 × 20 × 9 ft · 3,960 ft³21×2.8 min
Workshop40 × 30 × 12 ft · 14,400 ft³5.8×10 min
Warehouse bay100 × 50 × 16 ft · 80,000 ft³1.1×57 min

A circulation fan does not by itself replace indoor air. Exhaust airflow depends on a makeup-air path and system resistance. Use installed outdoor airflow for ventilation calculations.

Formula: airflow × 60 ÷ room volume. CDC explains the ventilation form of this equation; here the input is a catalog rating, so the result is a volume comparison.

Work it out for your own room →

Operating estimate

What could it cost to run?

This uses the listed 310 W power draw. The example below assumes 8 hours a day, 250 days a year, at $0.16 per kWh. Change the assumptions for your utility rate and schedule.

$99estimated electricity cost per year

This is an energy estimate, not a bill. Draw can vary by speed, supply voltage, controls, and the fan's actual load.

Listing details

What we know about this listing

Listing data was imported on September 14, 2026. Each specification can have a different source-check date; the evidence below is the most precise source information available here.

Sources for 14 listed specifications

Photos illustrate the listed model. Confirm the current variant, included hardware, and finish with the seller before purchase.

See all →

Like-for-like comparison

See this fan against a close category alternative.

Compare the listed specifications and the practical tradeoffs in one view.

Open comparison