Dri-Eaz · Air mover · Medium airflow

Dri-Eaz Vortex F174 Ventilation Fan

Dri-Eaz Vortex F174 Ventilation Fan
  • Dri-Eaz Vortex F174 Ventilation Fan, view 2
  • Dri-Eaz Vortex F174 Ventilation Fan, view 3
  • Dri-Eaz Vortex F174 Ventilation Fan, view 4
  • Dri-Eaz Vortex F174 Ventilation Fan, view 5
  • Dri-Eaz Vortex F174 Ventilation Fan, view 6
  • 2,041 CFMon high
  • 1 HPmotor

Amazon shows the current price, delivery and seller. As an Amazon Associate we earn from qualifying purchases.

Specs cited from Amazon listing ↗Photos: Amazon listing ↗ · refreshed Oct 31, 2026

Dri-Eaz Vortex F174 Ventilation Fan is an air mover.

What works

  • 2,041 CFM rated airflow on high
  • 1 HP motor

What doesn't

  • Drying performance depends on placement and room conditions

Who it's for

Good fit

  • Directed air movement for drying or circulation

Look elsewhere if

  • You need a permanently mounted exhaust installation

A good fit for your job? Check the current price and delivery.

See price on Amazon

Dri-Eaz Vortex F174 Ventilation Fan is an air mover.

Choose the outlet direction and placement for the surface being dried. A room-circulation rating does not establish contaminant removal or drying time.

Before you buy

Installation and buying checks

Use these questions to verify the exact configuration. Linked facts are cited; unlisted details stay questions.

  1. Mounting and support

    What mounting method and hardware does the exact unit require?

  2. Clearance and handling

    What are the installed dimensions, weight, and clearances?

  3. Electrical match

    What voltage and connection requirements does the exact unit specify?

  4. Airflow at the job

    Is the listed airflow rated at an operating point that matches the job after placement, obstructions, and system resistance are considered?

  5. Location requirements

    Does the site require an environmental rating or guard? Neither is listed here.

Put 2,041 CFM in context

The Dri-Eaz Vortex F174 Ventilation Fan has a listed airflow of 2,041 cubic feet per minute. The table compares this rated volume with example room volumes. It does not measure fresh-air exchange, air speed at your body, or room coverage.

RoomSizeNominal room volumes / hourNominal pass interval
One-car garage22 × 12 × 9 ft · 2,376 ft³52×1.2 min
Two-car garage22 × 20 × 9 ft · 3,960 ft³31×1.9 min
Workshop40 × 30 × 12 ft · 14,400 ft³8.5×7.1 min
Warehouse bay100 × 50 × 16 ft · 80,000 ft³1.5×39 min

A circulation fan does not by itself replace indoor air. Exhaust airflow depends on a makeup-air path and system resistance. Use installed outdoor airflow for ventilation calculations.

Formula: airflow × 60 ÷ room volume. CDC explains the ventilation form of this equation; here the input is a catalog rating, so the result is a volume comparison.

Work it out for your own room →